3 Wiring and Connection
3.1.2 Main Circuit Wire
3-10
For Three-phase, 400 V
Use SERVOPACKs and converters in the specified combinations.
Combination of SERVOPACK and
Converter
*
Terminal Symbols
Screw Size for
Terminals
Tightening
Tor qu e
(Nm)
Wire Size AWG
SGDV-750J
SGDV-
COA3ZDA
SERVOPACK
P, N M8 15.0
Bus bar attached
to the converter
U, V, W M8 3.0 3
DU, DV, DW M6 3.0 10
M8 9.0 to 11.0 3
Converter
P, N M 8 3 . 0
Bus bar attached
to the converter
L1, L2, L3 M8 3.0 3
1, 2
M8 3.0 3
CN101
(24 V, 0 V)
(Connector)
–14
B1, B2 M8 3.0 8
M8 9.0 to 11.0 3
SGDV-101J
SGDV-
COA5EDA
SERVOPACK
P, N M8 15.0
Bus bar attached
to the converter
U, V, W M8 3.0 1
DU, DV, DW M6 3.0 10
M8 9.0 to 11.0 1
Converter
P, N M10 12 to 20
Bus bar attached
to the converter
L1, L2, L3 M10 12 to 20 2
1, 2
M10 12 to 20 2
CN101
(24 V, 0 V)
(Connector)
–14
B1, B2 M10 12 to 20 8
M8 9.0 to 11.0 2
SGDV-131J
SGDV-
COA5EDA
SERVOPACK
P, N M10 12 to 20
Bus bar attached
to the converter
U, V, W M10 30.0 2/0
DU, DV, DW M6 3.0 10
M8 9.0 to 11.0 2/0
Converter
P, N M10 12 to 20
Bus bar attached
to the converter
L1, L2, L3 M10 12 to 20 2/0
1, 2
M10 12 to 20 2/0
CN101
(24 V, 0 V)
(Connector)
–14
B1, B2 M10 12 to 20 4
M8 9.0 to 11.0 2/0