Chapter 16 Port Authentication
GS3700/XGS3700 Series User’s Guide
193
Figure 133 Advanced Application > Port Authentication > MAC Authentication (Stacking mode)
The following table describes the labels in this screen.
Table 81 Advanced Application > Port Authentication > MAC Authentication
LABEL DESCRIPTION
Active Select this check box to permit MAC authentication on the Switch.
Note: You must first enable MAC authentication on the Switch before configuring it on each
port.
Name Prefix Type the prefix that is appended to all MAC addresses sent to the RADIUS server for
authentication. You can enter up to 32 printable ASCII characters.
If you leave this field blank, then only the MAC address of the client is forwarded to the
RADIUS server.
Password Type the password the Switch sends along with the MAC address of a client for
authentication with the RADI US server. You can enter up to 32 printable ASCII characters.
Timeout Specify the amount of time before the Switch allows a client MAC address that fails
authentication to try and authenticate again. Maximum time is 3000 seconds.
When a client fails MAC authentication, its MAC address is learned by the MAC address
table with a status of denied. The timeout period you specify here is the time the MAC
address entry stays in the MAC address table until it is cleared. If you specify 0 for the
timeout value, the Switch uses the Aging Time configured in the Sw itch Setup screen.
Note: If the Aging Time in the Switch Setup screen is set to a lower value, then it
supersedes this setting. See
Section 6.4 on page 63.
Slot (Stacking
mode)
This field appears only in stacking mode. Click the drop-down list to choose the slot
number of the Switch in a stack.
Port (Standalone
or stacking
mode)
This field displays the port number. In stacking mode, the first box field is the slot ID and
the second field is the port number.