Chapter 59 Access Control
XGS4600 Series User’s Guide
548
reset zySysMgmtUncontrolledSystem
Reset
1.3.6.1.4.1.890.1.15
.3.49.2.1
This trap is sent when the Switch
automatically resets.
zySysMgmtControlledSystemR
eset
1.3.6.1.4.1.890.1.15
.3.49.2.2
This trap is sent when the Switch resets by an
administrator through a management
interface.
zySysMgmtBootImageInconsist
ence
1.3.6.1.4.1.890.1.15
.3.49.2.3
This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
through the CLI.
RebootEvent 1.3.6.1.4.1.890.1.5.
1.1.2
This trap is sent when the Switch reboots by
an administrator through a management
interface.
timesync zyDateTimeTrapTimeServerNot
Reachable
1.3.6.1.4.1.890.1.15
.3.82.3.1
This trap is sent when the Switch’s date and
time is not manually entered or the specified
time server is not reachable.
zyDateTimeTrapTimeServerNot
ReachableRecovered
1.3.6.1.4.1.890.1.15
.3.82.3.2
This trap is sent when the Switch’s real time
clock is up to date.
loopguard zyLoopGuardLoopDetect 1.3.6.1.4.1.890.1.15
.3.45.2.1
This trap is sent when loopguard shuts down
a port.
errdisable zyErrdisableDetect 1.3.6.1.4.1.890.1.15
.3.24.4.1
This trap is sent when an error is detected on
a port, such as a loop occurs or the rate limit
for specific control packets is exceeded.
zyErrdisableRecovery 1.3.6.1.4.1.890.1.15
.3.24.4.2
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.
poe
(For PoE models
only)
pethPsePortOnOffNotification 1.3.6.1.2.1.105.0.1 This trap is sent when the PoE port delivers
power or delivers no power to a PD.
pethMainPowerUsageOnNo
tification
1.3.6.1.2.1.105.0.2 This trap is sent when the usage power is
above the usage indication threshold.
pethMainPowerUsageOffNo
tification
1.3.6.1.2.1.105.0.3 This trap is sent when the usage power is
below the usage indication threshold.
zyPoePowerPortOverload 1.3.6.1.4.1.890.1.15
.3.59.4.1
This trap is sent when the port is turned off to
supply power due to overloading.
zyPoePowerPortShortCircuit 1.3.6.1.4.1.890.1.15
.3.59.4.2
This trap is sent when the port is turned off to
supply power due to short circuit.
zyPoePowerPortOverSystemBu
dget
1.3.6.1.4.1.890.1.15
.3.59.4.3
This trap is sent when the port is turned off to
supply power because the requested power
exceeds the total PoE power budget on the
Switch.
zyPoePowerPortOverloadReco
vered
1.3.6.1.4.1.890.1.15
.3.59.4.5
This trap is sent when the port is turned on to
recover from an overloaded state.
zyPoePowerPortShortCircuitRe
covered
1.3.6.1.4.1.890.1.15
.3.59.4.6
This trap is sent when the port is turned on to
recover from a short circuit.
zyPoePowerPortOverSystemBu
dgetRecovered
1.3.6.1.4.1.890.1.15
.3.59.4.7
This trap is sent when the port is turned on to
recover from an over system budget.
Table 266 SNMP System Traps (continued)
OPTION OBJECT LABEL OBJECT ID DESCRIPTION