1-17
Parameters
date: Specifies to adopt the current system date and time, in the format of Mmm dd hh:mm:ss:ms yyyy.
no-year-date: Specifies to adopt the current system date and time excluding the year, in the format of
Mmm dd hh:mm:ss:ms.
none: Specifies not to include time stamp in the output information.
Description
Use the info-center timestamp loghost command to set the format of time stamp for the output
information sent to the log host.
Use the undo info-center timestamp loghost command to restore the default setting of time stamp
format.
By default, the date time stamp is adopted.
Examples
# Set the no-year-date time stamp for the output information sent to the log host.
<Sysname> system-view
System View: return to User View with Ctrl+Z.
[Sysname] info-center timestamp loghost no-year-date
info-center trapbuffer
Syntax
info-center trapbuffer [ channel { channel-number | channel-name } | size buffersize ]*
undo info-center trapbuffer [ channel | size ]
View
System view
Parameters
size: Sets the size of the trap buffer.
buffersize: Size of the trap buffer, represented by the number of messages it holds. It ranges from 0 to
1,024 and defaults to 256.
channel: Sets the channel through which information is output to the trap buffer.
channel-number: Channel number, ranging from 0 to 9, corresponding to the 10 channels of the
system.
channel-name: Channel name. By default, the name of channel 0 to channel 9 is (in turn) console,
monitor, loghost, trapbuffer, logbuffer, snmpagent, channel6, channel7, channel8, channel9.
Description
Use the info-center trapbuffer command to enable information output to the trap buffer.
Use the undo info-center trapbuffer command to disable information output to the trap buffer.
By default, information output to the trap buffer is enabled with channel 3 (trapbuffer) as the default
channel and a maximum buffer size of 256.
This command takes effect only after the information center function is enabled.