Operational functionality and motor cable lengthMaximum recommended mo-
tor cable length
The drive is designed to operate with optimum performance with the following
maximum motor cable lengths.
Maximum motor cable length, 4 kHzFrame size
Vector controlScalar control
ftmftm
Standard drive, without external options
330100330100R0*
330100330100R1*
330100330100R2*
990300990300R3
990300990300R4
990300990300R5
990300990300R6
990300990300R7
990300990300R8
3AXD10000715646.xls A
Note:
In multi-motor system, the sum of all motor cable lengths shall not exceed
that given in the following table.
*)Conducted and radiated emissions of these motor cable lengths do not
comply with EMC requirements.
EMC compatibility and motor cable length
To comply with the European EMC Directive (standard EN 61800-3), use the following
maximum motor cable lengths at 4 kHz switching frequency. See the table below.
Maximum motor cable length, 4 kHzFrame size
ftm
EMC limits for Category C3
1)
Standard drive with an internal EMC filter.
See notes 3 and 4.
10030R0
10030R1
10030R2
330100R3
330100R4
330100R5
Technical data 125

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACQ80-04 Series and is the answer not in the manual?

ABB ACQ80-04 Series Specifications

General IconGeneral
BrandABB
ModelACQ80-04 Series
CategoryController
LanguageEnglish

Related product manuals