Page #127 background image
Max. 20 mA outputReference voltage output for
analog inputs +10V DC (Term.
4)
Inaccuracy: ±1%
24 V DC logic levels: "0" < 5 V, "1" > 13 VSafe torque off (STO) inputs
IN1 and IN2 (Term. 37 and 38)
R
in
: 2.47 kohm
Maximum cable length 300 m (984 ft) between activation switch (K) and drive
control board, see sections Wiring (page 149) and Safety data (page 160).
STO cable
EIA-485, male RJ-45 connector, max. cable length 100 mControl panel - drive connec-
tion
USB Type Mini-B, max. cable length 2 mControl panel - PC connection
Technical data 127