2.12 FBA MAIN CW Pb 0 …
0xFFFFFFFF
- 1 = 1 500 µs 32 WP 95
2.13 FBA MAIN SW Pb 0 …
0xFFFFFFFF
- 1 = 1 500 µs 32 WP 98
2.14 FBA MAIN REF1 INT32 -2
31
…2
31
- 1 - 1 = 1 500 µs 32 WP 99
2.15 FBA MAIN REF2 INT32 -2
31
…2
31
- 1 - 1 = 1 500 µs 32 WP 99
2.16 FEN DI STATUS Pb 0…0x33 - 1 = 1 500 µs 16 WP 99
2.17 D2D MAIN CW Pb 0…0xFFFF - 1 = 1 500 µs 16 WP 100
2.18 D2D FOLLOWER CW Pb 0…0xFFFF - 1 = 1 2 ms 16 WP 100
2.19 D2D REF1 REAL -2
31
…2
31
- 1 - 1 = 1 500 µs 32 WP 100
2.20 D2D REF2 REAL -2
31
…2
31
- 1 - 1 = 1 2 ms 32 WP 100
03 CONTROL VALUES
3.01 SPEED REF1 REAL -30000…30000 rpm 1 = 100 500 µs 32 WP 101
3.02 SPEED REF2 REAL -30000…30000 rpm 1 = 100 500 µs 32 WP 101
3.03 SPEEDREF RAMP IN REAL -30000…30000 rpm 1 = 100 500 µs 32 WP 101
3.04 SPEEDREF RAMPED REAL -30000…30000 rpm 1 = 100 500 µs 32 WP 101
3.05 SPEEDREF USED REAL -30000…30000 rpm 1 = 100 250 µs 32 WP 101
3.06 SPEED ERROR FILT REAL -30000…30000 rpm 1 = 100 250 µs 32 WP 101
3.07 ACC COMP TORQ REAL -1600…1600 % 1 = 10 250 µs 16 WP 101
3.08 TORQ REF SP CTRL REAL -1600…1600 % 1 = 10 250 µs 16 WP 101
3.09 TORQ REF1 REAL -1000…1000 % 1 = 10 500 µs 16 WP 101
3.10 TORQ REF RAMPED REAL -1000…1000 % 1 = 10 500 µs 16 WP 101
3.11 TORQ REF RUSHLIM REAL -1000…1000 % 1 = 10 250 µs 16 WP 101
3.12 TORQUE REF ADD REAL -1000…1000 % 1 = 10 250 µs 16 WP 101
3.13 TORQ REF TO TC REAL -1600…1600 % 1 = 10 250 µs 16 WP 101
3.14 BRAKE TORQ MEM REAL -1000…1000 % 1 = 10 2 ms 16 WP x 101
3.15 BRAKE COMMAND enum 0…1 - 1 = 1 2 ms 16 WP 102
3.16 FLUX REF USED REAL24 0…200 % 1 = 1 2 ms 16 WP 102
3.17 TORQUE REF USED REAL -1600…1600 % 1 = 10 250 µs 32 WP 102
3.20 MAX SPEED REF REAL 0…30000 rpm 1 = 100 2 ms 16 WP 102
3.21 MIN SPEED REF REAL -30000…0 rpm 1 = 100 2 ms 16 WP 102
4 POS CTRL VALUES
4.01 SPEED REF POS REAL -32768…32768 rpm 1 = 100 250 µs 32 WP 103
4.02 SPEED ACT LOAD REAL -32768…32768 ** See 60.10 500 µs 32 WP 103
4.03 PROBE1 POS MEAS REAL -32768…32768 * See 60.09 2 ms 32 WP 103
4.04 PROBE2 POS MEAS REAL -32768…32768 * See 60.09 2 ms 32 WP 103
4.05 CYCLIC POS ERR REAL -32768…32768 * See 60.09 2 ms 32 WP 103
4.06 POS REF REAL -32768…32768 * See 60.09 500 µs 32 WP 103
4.07 PROF SPEED REAL -32768…32768 ** See 60.10 500 µs 32 WP 103
4.08 PROF ACC REAL 0…32768 ** See 60.10 500 µs 32 WP 103
4.09 PROF DEC REAL -32768…0 ** See 60.10 500 µs 32 WP 103
4.10 PROF FILT TIME REAL 0…1000 ms 1 = 1 500 µs 16 WP 103
4.11 POS STYLE Pb 0…0x1FF - 1 = 1 500 µs 16 WP 103
4.12 POS END SPEED REAL 0…32768 ** See 60.10 500 µs 32 WP 104
4.13 POS REF IPO REAL -32768…32768 * See 60.09 500 µs 32 WP 104
Index Name Type Range Unit FbEq Update