Alarm Signals
Alarm signals appear as flashing red LEDs below the display. They
indicate:
• Dev. Temp. Incor.: Developer temperature too high or low
• Low Level: Low level in the developer or fix tanks
• Repl. Empty: Low level in the replenishment containers
• Waste Full: N/A
The SelectSet Avantra displays error 27, Processor Alarm Signal when
any of these errors occur. In this case, the imagesetter finishes the cur-
rent job, but will not image another job or advance media until you
clear the processor error. As soon as you correct the error, the error at
the imagesetter is cleared.
Note: When you adjust the processor to clear a
Dev. Temp.. Incor. alarm, the imagesetter waits
until the developer has been at the correct tem-
perature for about one minute before the error 27
message is cleared.
Status Signals
Status signals appear as solid red LEDs below the display. They indi-
cate:
• Film Input Left: Media is entering the processor
• Film Input Right: Media is entering the processor
Function Keys
Function keys enable you to view and change parameters for the dif-
ferent processor operations.
Avantra 20/25 OLP: Processor Operation
•
9–5