Programming
The processor can store nine different programs that control develop-
ing time, dryer temperature, and and replenishment rates.
Programs 1, 2, and 3 are preset with the values listed below.
Preset Values
Function (Unit) Program 1 Program 2 Program 3
Dev. time (sec.) 30 30 40
Dev. temp. (
°C) 25 25 25
Fix. temp. (
°C) 23 23 23
Dry temp. (
°C) 50 45 40
Dev. repl. (cc/m2) 250 250 250
Fix. repl. (cc/m2) 375 375 375
Dev. stdby. (cc/24hr.) 1000 1000 1000
Fix. stdby. (cc/24hr.) 1000 1000 1000
Note: Programs 4 through 9 are identical to Program 3.
Selecting Programs
Press PROG to select a different program.
Each time you press PROG, the next program is selected. The program
number appears on the left side of the control panel display. You scroll
through the programs in numerical order.
Revising Programs
Any changes you make to the preset values are stored as part of the
current program. For example, if you have selected program 2 and you
change the dryer temperature, the new temperature is incorporated
into program 2.
All nine programs have the same developer and fixer temperatures. For
example, if you change the fixer temperature for program 1, all pro-
grams use the new fixer temperature.
Avantra 20/25 OLP: Processor Operation
•