Dryer Saver
When this function is On (the default setting), the dryer is in standby
mode. When switched to Off, the display reads DRYER SAVER OFF
and the heating elements and dryer run continuously at the preset
temperature.
Man. Repl.
Controls manual replenishment of developer and fixer. When you press
MAN REPL, 100 cc. of both developer and fixer are pumped into the
tanks.
Man. Start
Press MAN START to start up the drive motor, the circulation pumps,
and the dryer. The display reads P
x MANUAL START, where x is the
number of the selected program. For example, P1 MANUAL START.
Press the MAN START again to return to the ready/idle mode.
Note: No replenisher is released in MAN START mode.