Wipe down all rollers above the solution level.
Use a separate rag for developer rollers. A cleaning sheet can be
used as an alternative to wiping down the rollers. A cleaning sheet
can be any pre-processed media that is at least 18 inches (46 cm)
long.
Make sure that the water supply is adequate.
The processor can be equipped with a wash recirculator or a direct
water supply. If your system has a wash recirculator, make sure
that the water level is high enough. If you use a direct water sup-
ply, make sure that the valve feeding the processor is open and that
enough water is flowing.
Check the development time, temperature, and replenishment
settings at the processor.
Check these settings every time you process media.
Note: To prevent the growth of algae in the wash tank,
drain the tank at the end of each day.
Weekly Maintenance
Follow this weekly maintenance procedure:
Pull the wash rack and drain the wash section.
Clean and wipe down the wash tank. If algae buildup is a problem,
clean the inside of the tank with bleach and rinse well. Clean the
wash roller rack with warm water.
Note: Never put racks on the dryer cover. Chemicals
may run into the wiring.
Change developer filters.
Change the developer filter every 40 working hours.
Clean the wash recirculator (U.S. Only).
(Not all systems are equipped with a wash recirculator.) Remove and
replace the filter; wipe down the tank and fill with fresh water.