Service Management Tasks
Page 142 7210 SAS D, E, K OS Quality of Service Guide
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
meter 2
multicast-meter 12
exit
dot1p 2 fc af profile out
exit
egress
fc af
exit
fc be
exit
fc ef
exit
fc h1
exit
fc h2
exit
fc l1
exit
fc l2
exit
fc nc
exit
exit
exit
The number of classification entries (TC) used is calculated, as follows:
(2 * 0)nc + (2 * 0)h1 + (2 * 0)ef + (2 * 0)h2 + (2 * 0)l1 + (2 * 1)af + (2 * 0)l2 + (2 * 1)be = 4
The number of meters (TP) user are: 4 (Meters 1,2,9,12)
Example 3
network 3 create
description “network-policy-3”
ingress
default-action fc be profile out
meter 1 create
exit
meter 2 create
exit
meter 9 multipoint create
exit
meter 12 multipoint create
exit
fc "af" create
meter 2
multicast-meter 12
exit
fc "be" create

Table of Contents