Service Management Tasks
Page 144 7210 SAS D, E, K OS Quality of Service Guide
Example 4
network 4 create
description “network-policy-4”
ingress
default-action fc be profile out
meter 1 create
exit
meter 9 multipoint create
exit
dot1p 1 fc l2 profile in
dot1p 2 fc af profile out
dot1p 3 fc af profile in
dot1p 4 fc h2 profile in
dot1p 5 fc ef profile in
dot1p 6 fc h1 profile in
dot1p 7 fc nc profile in
exit
egress
fc af
exit
fc be
exit
fc ef
exit
fc h1
exit
fc h2
exit
fc l1
exit
fc l2
exit
fc nc
exit
exit
exit
The number of Filter-Entries (TC) used is calculated, as follows:
(2 * 1)nc + (2 * 1)h1 + (2 * 1)ef + (2 * 1)h2 + (2 * 0)l1 + (2 * 2)af + (2 * 1)l2 + (2 * 1)be = 16
The number of meters (TP) used are: 2 (Meters 1,9).