Page 268 7210 SAS D, E, K OS Quality of Service Guide
FCnc = 1 + 0 + 0 + 0 = 1
FCh1 = 1 + 0 + 0 + 0 = 1
FCef = 1 + 0 + 0 + 0 = 1
FCh2 = 1 + 0 + 0 + 0 = 1
FCl1 = 1 + 0 + 0 + 0 = 1
FCaf = 1 + 0 + 0 + 0 = 1
FCl2 = 0 + 0 + 0 + 0 = 0
FCbe = 1 + 0 + 0 + 0 = 1
Using the above equation, the total classification entries used = 7 and meters used = 4.
As can be seen here, using the same policy for Epipe SAP can lead to inefficient use of resources.
Hence, it is recommended to create a different policy with the required number of resources (that
is,with num-qos-classifiers 8).
Example 5
sap-ingress 10 create
num-qos-classifiers 72
meter 1 create
exit
meter 3 create
exit
meter 4 create
exit
meter 11 multipoint create
exit
fc "af" create
meter 3
broadcast-meter 11
multicast-meter 4
exit
fc "be" create
meter 1
broadcast-meter 11
exit
ip-criteria
entry 1 create
match
dscp be
exit
action fc "af"
exit
entry 2 create
match
dscp cp1
exit
action fc "af"
exit
entry 3 create
match
dscp cp3
exit
action fc "af"
exit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alcatel-Lucent 7210 SAS Series and is the answer not in the manual?

Alcatel-Lucent 7210 SAS Series Specifications

General IconGeneral
BrandAlcatel-Lucent
Model7210 SAS Series
CategorySwitch
LanguageEnglish

Related product manuals