NTP 160 — Install an I-211M-K or I-211M-L indoor ONT
NTP 160-6 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Figure NTP 160-3: Fiber cable routing for the I-211M-L ONT within the Just Inside
enclosure
iii For the I-211M-L ONT, route the SC/APC fiber optic cable to the ONT as
shown in Figure NTP 160-3.
iv Position the I-211M-L indoor ONT within the Just Inside enclosure, as
shown in Figure NTP 160-8.
v Secure the I-211M-L indoor ONT within the Just Inside enclosure.
vi Go to step 6.
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Note — Observe the following:
• Do not overtighten the ONT bracket when securing the I-211M-L
indoor ONT to the Just Inside enclosure. The unit can become
skewed and compromise the environmental seal of the ONT mounted
in the outdoor enclosure.
Silence
Alarm
System Status
Battery Power
Replace Battery
Auxillary Power
Battery
Emergency Use
22759
Fiber optic
cable
ONT
mounting
hole
Locking screw