VLL Services
7705 SAR OS Services Guide Page 223
A:ALU-42>config>service# info
-------------------------------------
...
apipe 5 customer 1 create
description "apipe test"
service-mtu 1400
sap 2/2/2.1:0/32 create
accounting-policy 2
ingress
qos 102
exit
egress
qos 103
exit
exit
spoke-sdp 1:4 create
egress
vc-label 18431
ingress
vc-label 2048
exit
no shutdown
exit
...
-------------------------------------
A:ALU-42>config>service#
Disabling a Service
A service can be shut down without deleting the service parameters.
Use the
shutdown command to shut down a VLL service. The following CLI syntax
displays the command to shut down an Apipe service. Use a similar syntax to shut down
Cpipe, Epipe, and Ipipe services.
CLI Syntax: config>service#
apipe service-id
shutdown
PE router 1 (A:ALU-41):
Example: A:ALU-41>config>service# apipe 5
A:ALU-41>config>service>apipe# shutdown
A:ALU-41>config>service>apipe# exit
PE router 2 (A:ALU-42):
Example: A:ALU-42>config>service# apipe 5
A:ALU-42>config>service>apipe# shutdown
A:ALU-42>config>service>apipe# exit