VLL Services Command Reference
Page 256 7705 SAR OS Services Guide
dual-ended-loss-test-enable
Syntax [no] dual-ended-loss-test-enable
Context config>service>epipe>sap>eth-cfm>mep
config>service>epipe>spoke-sdp>eth-cfm>mep
Description This command enables dual-ended loss measurement testing on a MEP. When enabled, the test runs
in the background.
CCM must be enabled before the dual-ended loss measurement test can be enabled.
The dual-ended and single-ended loss measurement tests are mutually exclusive tests. When the dual-
ended loss measurement test is enabled, the single-ended test is not available.
The no form of the command disables the dual-ended loss measurement test.
Default enabled
alarm-threshold
Syntax alarm-threshold percentage
[no] alarm-threshold
Context config>service>epipe>sap>eth-cfm>mep>dual-ended-loss-test-enable
config>service>epipe>spoke-sdp>eth-cfm>mep>dual-ended-loss-test-enable
Description This command specifies the alarm threshold ratio for frame loss measurement, where percentage is
defined as (the total number of Tx frames) divided by (the total number of frames dropped) expressed
as a percentage. When the alarm threshold is reached, an alarm is raised.
The no form of the command removes the priority value from the configuration. Setting the
percentage to 0.00 is equivalent to using the no form of the command.
Parameters percentage — 0.00 to 100.00, adjustable in 0.01% increments
Default 0.25
Values