Internet Enhanced Service
7705 SAR OS Services Guide Page 363
bfd
Syntax bfd transmit-interval [receive receive-interval] [multiplier multiplier]
no bfd
Context config>service>ies>interface
Description This command configures the time interval in which BFD control messages are transmitted and
received on the interface. The multiplier parameter specifies the number of consecutive BFD
messages that must be missed by the peer node before the BFD session closes and the upper layer
protocols (OSPF, IS-IS, BGP) are notified of the fault.
no bfd
Parameters transmit-interval — the number of milliseconds between consecutive BFD sent messages
Values 100 to 100000
Default 100
receive-interval — the number of milliseconds between consecutive BFD received messages
Values 100 to 100000
Default 100
multiplier — the number of consecutive BFD messages that must be missed before the interface is
brought down
Values 3 to 20
Default 3
ip-mtu
Syntax ip-mtu octets
no ip-mtu
Context config>service>ies>interface
Description This command configures the IP maximum transmit unit (packet size) for this interface.
The no form of the command returns the default value.
Parameters octets — the MTU for the interface
Values 512 to 2048