EasyManua.ls Logo

Alstom Reason RPV311 - Direct Ethernet Communication

Alstom Reason RPV311
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 14 Communications
RPV311
RPV311-TM-EN-6
255
4 DIRECT COMMUNICATION USING THE ELECTRICAL
ETHERNET PORT
For local communication with equipment using the electrical Ethernet port, connect a crossover
10/100BaseT Ethernet cable, with RJ45 connector, between the computer and the equipment, as shown in
Figure 98 The crossover Ethernet cable should have the following pinout:
568 A
568 B
1 White / green stripe
3 White / orange stripe
2 Green solid
6 Orange solid
3 White / orange stripe
1 White / green stripe
4 Blue solid
4 Blue solid
5 White / blue stripe
5 White / blue stripe
6 Orange solid
2 Green solid
7 White / brown stripe
7 White / brown stripe
8 Brown solid
8 Brown solid
Figure 98: Local communication with equipment using the electrical Ethernet port architecture
In local communication with the equipment, it is necessary that the device and the computer be on the same
network. To achieve this, configure the network connection of the computer according to the IP address,
Broadcast and Netmask of the equipment, as shown below: