Chapter 17 Technical Specifications
RPV311
RPV311-TM-EN-6
327
Limits:
0.15 to 0.50MHZ - 79dB(μV) quasi peak; 66dB(μV) average
0.5 to 30MHz - 73dB(μV) quasi peak; 60dB(μV) average
3.12 SAFETY TESTS
Safety tests
Safety
IEC 61010-1
IEC 60255-5
Inpulse - 5KV
Dielectric withstand - 3,3KVDC for 60 seconds
Insulation > 100M Ω
3.13 ENVIRONMENTAL TESTS
Environmental tests
IEC 60068-2-1
-40°C, 16 hours (Cold)
IEC 60068-2-2
+85°C, 16 hours (Dry heat)
IEC 60068-2-30
95% no condensation, 55°C (Damp heat)
IEC 60068-2-14
-40°C to 85ºC / 9 hours / 2 cycles (Change of temperature)
IEC 60255-21-1
Class 2 (Vibration)
IEC 60255-21-2
Class 1 (Shock)
3.14 ENCLOSURE PROTECTION IEC 60529
Enclosure Protection IEC 60529