132
ML-5120A
3. Operating Procedure
4
Stopping Laser Processing
CAUTION
During a laser light output or for 5 seconds immediately after a laser light output, do
not turn OFF the MAIN POWER switch.
(1) Press the "LD", "BEAM" and "GUIDE" setting buttons on each screen to set them
to OFF.
(2) Turn OFF the CONTROL keyswitch.
The key can be pulled out.
(3) Turn OFF the MAIN POWER switch.
The power supply is turned OFF and the POWER lamp goes out.
⇒
Return the key of the CONTROL keyswitch to the laser safety supervisor so that
it can be kept in custody.