140
ML-5120A
3. Connector Functions
Pin No. Description
9
Unused
Do not connect anything.
10
Unused
Do not connect anything.
11
Unused
Do not connect anything.
12
Stage end (only for AHC external I/O (option))
When [END] of the relevant stage is selected, this pin closed internally for the time
specied in [STAGE-END SIGNAL WIDTH] at the end of the stage.
This may be continuous with the next stage end signal.
13
Unused
Do not connect anything.
14 Output COM