3. Changing the Equipment Settings
89
ML-5120A
Chapter 2 Various Settings
Introduction Part
Installation and
Preparation Part
Operating Part Maintenance Part Appendixes
Displaying the INITIALIZE Screen
(1) Turn OFF the CONTROL keyswitch and turn ON the MAIN POWER switch.
Power is supplied and the POWER lamp comes on.
(2) While the KEY SWITCH CHECK screen is displayed, press the "INITIALIZE" but-
ton and the right button (red portion in the above gure) of the laser controller
simultaneously.
The INITIALIZE screen appears.
Unless the CONTROL keyswitch is OFF, the KEY SWITCH CHECK screen does
not appear.