User Manual Rev BE AMETEK Programmable Power
MX Series 118
INST PK CURR This readout reflects the instantaneous peak current
value detected at the output. This value is updated
continuously and does not require a reset operation like
the PEAK CURR readout. The instantaneous peak
current does not use a track and hold mechanism like
the PEAK CURR measurement in the MEASUREMENT 2
screen. Instead, it tracks the peak current on a cycle-
by-cycle basis. The INST PK CURR typically tracks the
rms current and the crest factor.
UPDATE PROGRAM FUNCTIONS FROM MEASUREMENT SCREEN
The Shuttle can be used to update program parameters such as voltage,
frequency or current from the measurement screen. This can be achieved with
the following sequence:
1) Select the program 1 screen using the PROG key.
2) Use the up and down key to select the desired function to
update. (Selects parameter that will be changed by the shuttle
once in the MEAS1 screen)
3) Select the measurement 1 screen by pressing the MEAS key.
4) The pointer symbol () points to the programmed parameter
(V, F or CL) that will be affected by turning the shuttle.

Table of Contents

Other manuals for Ametek MX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek MX Series and is the answer not in the manual?

Ametek MX Series Specifications

General IconGeneral
BrandAmetek
ModelMX Series
CategoryPower Supply
LanguageEnglish

Related product manuals