User Manual – Rev BE    AMETEK Programmable Power 
MX Series  153 
Note that the fourth configuration screen is only available on MX models with 
firmware revision 4.60 or higher. For units with older models, refer to the 
CONFIGURATION SETUP 3 screen. 
MB  This entry was moved from CONFIGURATION SETUP 3 
to CONFIGURATION SETUP 4. Its purpose remains the 
same. For details, see CONFIGURATION SETUP 3 
manual section on previous page. 
MANUAL  This field does not apply to MX products and is always 
set to N/A. 
OPT0, OPT1, OPT2  This field indicates the presence of the following three 
options: 
OPT0 = A350 Avionics option (-A350) 
OPT1 = AMD24 Avionics option (-AMD) 
OPT2 = B787 Avionics option (-B787) 
The scroll through the three available OPTn fields, use 
the shuttle. ON indicates the option is present, N/A 
indicates the option is not installed. 
LAN  This field indicates the presence of the LAN Ethernet 
interface option. ON indicates the option is present, N/A 
indicates the option is not installed. 
SNK  This field indicates the presence of the Current Sink 
regenerative mode option. ON indicates the option is 
present, N/A indicates the option is not installed. 
FC  This field, when ON, indicate the presence of the 
frequency control option. This option will cause the 
frequency to fluctuate ±0.25% of the program value.