enable the output. Verify the phase C module output is within
50mVolts of the C module in the master cabinet. If it is not,
adjust the pot behind the hole in the upper left corner of the
module so the C output matches the C master output within
50mVolts. Press the OUTPUT ON/OFF key to disable the
output.
9) If power system under adjustment is an MX135, then repeat
steps 6, 7 and 8 above for the second auxiliary cabinet.
10) Power down system and replace the wires to terminals 6 and 7
on the auxiliary power modules.