Page #313 background imageLoading...
Page #313 background image
User Manual – Rev BE AMETEK Programmable Power
MX Series 313
screen instead of the frequency shift. At this point, the EUT should shut down
due to an under-voltage condition. Finally, the output relay is opened after the
user set delay expires and the current still exceed the current limit set in the
REGENERATE CONTROL screen.
For the DC SNK mode the MX must be set to the DC Voltage mode and voltage
range that accepts the maximum desired set voltage. The OL Mode must be set
to constant current (CC). Refer to Paragraph 4.2.11 & UTILITY 1 for VOLT/
CURRENT CONTROL of the CC Mode.