User Manual Rev BE AMETEK Programmable Power
MX Series 319
Nu mb e r
Message String
Ca u s e
Re med y
operation such as programming frequency when
i n DC m o d e .
-201
"Invalid while in local"
Command issued but unit is not in
remote state
Put instrument in remote state before issuing
GPIB commands.
-203
"Command protected" Command is locked out
Some commands are supported by the unit but
are locked out for protection of settings and are
not user accessible.
-210
"Trigger error" Problem with trigger system.
Unit could not generate trigger for transient
execution or measurement.
-211
"Trigger ignored" Trigger request has been ignored.
Trigger setup incorrect or unit was not armed
when trigger was received. Check transient
system or measurement trigger system settings.
-213
"Init ignored" Initialization request has been ignored
Unit was told to go to armed state but was
unable to do so. Could be caused by incorrect
transient system or measurement acquisition
setup.
-220
"Parameter error" Parameter not allowed.
Incorrect parameter or parameter value. Check
programming manual for allowable parameters
-221
"Setting conflict"
Requested setting conflicts with other
setting in effect.
Check other settings. e.g., trying to program a
DC o f f s e t wh i l e i n AC mo d e
-222
"Dat a out of range"
Parameter data outside of allowable
range.
Check programming manual for allowable
parameter values
-223
"Too much data" More data received than expected
Check programming manual for number of
parameters or data block size
-224
"Illegal parameter value" Parameter value is not supported
Check programming manual for correct
parameters
-226
"Lists not same length"
One or more transient lists programmed
has different length.
All lists must be of same length or transient
cannot be compiled and executed.
-241
"Ha r dwa r e mis s in g " N/ A N/ A
-254
"Media full"
No storage space left to save settings or
data.
Delete other settings or data to make room.
-255
Directory full” Too many waveform directory entries
Delete one or more waveforms from waveform
memory to make room.
-256
File name not found Waveform requested not in directory
Ch e c k waveform directory for waveform names
present.
-257
File name error” Incorrect filename
Too many or non-AS CI I characters used in
waveform file definition.
-283
Illegal variable name” Variable name illegal. Use ASCII characters only
-300
"De vi ce specific error" Hardware related error Check hardware for proper operation.
-311
"Memory error" Waveform memory checksum error.
May be the result of incomplete user-defined
waveform download. Check interface and try
downloading waveform again. Successful
download may clear this error condition.
Alternatively, use TRAC:DEL:ALL command to
clear waveform memory.
-314
"Save/recall memory lost" User setup register contents lost Store setup in same register again.
-315
"Configuration memory lost" Hardware configuration settings lost.
Contact technical support at
techsupport.ppd@ametek.com
to obtain
instructions on restoring configuration data.
-333
"Self-test failed" Internal error
Contact service department at
repairs.ppd@ametek.com

Table of Contents

Other manuals for Ametek MX Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ametek MX Series and is the answer not in the manual?

Ametek MX Series Specifications

General IconGeneral
BrandAmetek
ModelMX Series
CategoryPower Supply
LanguageEnglish

Related product manuals