3.6.7 MX180, MX225, and MX270 Output Wiring Diagram
Figure 3-11 shows the required output connections for a MX180-3Pi through MX270-3Pi three phase output
configuration (rear-view perspective). For MX180, only 4 cabinets are used and for MX225 only 5 but otherwise the
wiring diagrams are the same so only the complete MX270-3Pi configuration is shown.
Always disconnect all input power from the MX180, MX225 or MX270 before removing the front panel cover that
provides access to the input and output terminal connections. Route the wires from the back of the MX45 chassis to
the front in the provided cable guides.
For any of these system configurations, it is recommended to use the optional wiring junction box (P/N 7003-416-1).
See section 3.13 for details. All output wires must be of equal length. It is advisable to place the master unit at or
near the physical center of the set of units.