4-55
4.3 CDMA Transmitter and Receiver Test --- TX and RX Tester Mode
• Function keys for Loop Back and Conversation States Analog receiver measurement:
1st page
[Analog RX Measure] F7: Displays the Analog RX Measure screen.
2nd page
[Setup Analog RX Parameter] F9:
Displays the Setup Analog RX Parameter screen.
• Function keys for call processing test:
1st page (None)
2nd page
[Setup Call Proc. Parameter] F9:Displays the Setup Call Proc. Parameter screen.
• Comment on the Call-Processing main function keys:
When DUT Control is set to Call Processing, the 2nd page is appeared.
The 2nd page indicates the call-processing trigger keys.
These 2nd-page main-function keys are displayed depending on the call processing status, as described below:
State 1: Stop state
Main function key --- [Start] F5
State 2: Idle and Idle-Reg states
Possible to perform TX/RX measurements in this state.
Main function keys --- [NW Originate] F2, [Register] F4, [Stop] F5
State 3: Loop Back and Conversation (communication) states
Possible to perform TX/RX measurement in this state.
Main function keys --- [NW Release] F2, [Stop] F5
State 4: Each sequence executing state in progress
Execution states of the sequences --- Registration, Origination, NW Originate, MS Release and NW Re-
lease
Main function key---[Stop] F5