B-5
Item Initial value Initialization
• TX RF Level/Power function key :
First page
[Ref level]F7 (MAIN) 30.0 dBm PW
(AUX) 22.0 dBm PW
[Strage Mode]F9 Normal PS
[Average Count]F9 10 PS
• Deviation function key :
First page
[Demod.]F7 FM PW
[Relative On Off]F8 Off PS
[Det Mode]F9 (P-P)/2 PW
[HPF]F10 Off PW
[LPF]F11 Off PW
Second page
[Strage Mode]F9 Normal PS
[Average Count]F9 10 PS
• Modulation function key :
[AF Osc.1 Frequency]F8 1.0040 kHz PW
[AF Osc.1 Deviation]F9 8.00 kHz PW
[AF Osc.1 On Off]F11 On PS
Second page
[AF Osc.2 Signal]F7
[AF Signal]F7 Tone PW
[Output for Mod AF]F8 Mod PW
[AF Osc.2 Frequency]F8 1.0040 kHz PW
[AF Osc.2 Deviation]F9 8.00 kHz (only for AF Osc.2 Signal=Mod) PW
[AF Osc.2 Level]F10 100.0 mV (only for AF Osc.2 Signal=AF) PW
[AF Osc.2 On Off]F11 Off PS
Second page
[External Deviation]F9 8.00 kHz PW
[External On Off]F11 Off PS
• RX RF Frequency function key :
[Incremental Step Value]F7 1.000 000 MHz PS
[Relative On Off]F8 Off PS
[Channel]F9 1 CH PW
• RX RF Level function key :
[Incremental Step Value]F7 1.0 dB PS
[Relative On Off]F8 Off PS
[Unit EMF TERM]F10 EMF PS
Appendix B Initial Values