SmartROC D65 T4F 10 Options
207 No: 713944459.6 en
è
The Calibrate rod tracker menu is opened.
4.
Select an index position in the carousel for each drill rod which has been added to the
system.
!
NOTE: Each drill rod can be placed in the carousel and has a ca-
rousel slot index. The drill rods can also be in a drill string and have
a position index.
n The first place in the carousel is at the drill rod extraction posi-
tion when the carousel has rotated clockwise to the mechanical
stop.
n The first drill rod position is the rod at the bottom of the string.
n The system prevents two drill rods being allocated the same
carousel slot index.
n The system ensures that each drill rod is given only one index
position in both the carousel and the drill string.
n When the drill rods are placed in a drill string, one of them must
have index 1. All subsequent index numbers must be success-
ive. If the drill rods are not in succession in the drill string, calib-
ration will fail.
Rod Tracker Graphical View
There is a menu with a graphic image of the current position of the carousel and drill string.
This menu makes it easier to check that the system corresponds to reality.