Connecting diagrams
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
102
of 218
7.12
X1 Service interface, see ZX1 - Service interface– on page 120
X2 Digital in- and outputs, e.g. pulse enable,
see ZX2 - Digital inputs/outputs– on page 121
X2:5 Input pulse enable, Low: not enabled, High: enabled (operation possible)
X3, X4 Connections for fieldbus EtherCAT
®
, VARAN, CANopen
®
, POWERLINK
®
, according to
the version also see ZX3 / X4 - fieldbus connection– on page 122
X6 Analog in- and outputs,
see ZX6 - analog inputs/outputs– on page 126
X7 Encoder analysis,
see ZX7 - encoder connection– from page 127
X101 Connection motor temperature
see ZX101 - motor temperature– on page 143
X102 Connection STO
see ZX102 - safe torque off - option– on page 143
X107 Motor, also see ZRequirements to the motor– on page 28 and
ZX107 - motor connection– on page 144
X200 Connections for the 24 V-voltage supply (SELV/PELV),
see ZRequirements to the control voltage / 24 V-supply– on page 28 and ZX200 - 24V
voltage supply– on page 137
X202 Power supply,
see ZRequirements to the energy supply: power supply– from page 27 and
ZX202, X203, X205 - power supply, DC link, ballast resistor connection– on page 138
X203 Power supply and ballast resistor connection,
see ZRequirements to the energy supply: power supply– from page 27 and
ZX202, X203, X205 - power supply, DC link, ballast resistor connection– on page 138
X300 Signal bus, connection to further units
see ZX300 - signal bus– on page 140
PE PE-connection,
see ZPE connection and RCD compatibility– from page 89 and
ZPE connections BM3200, BM3300 rear panel– on page 145
F1 Fuses (cable + device)
see ZProtection of the device and accordingly of the cable
– from page 88
F2 Fuse for the 24 V-voltage supply
K1 Mains contactor (optional)