Installation
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11
131
of 218
7
Sine or
square wave
encoder
evaluation
The encoders, which meet the following technical specifications, can be used:
Voltage supply 5 V
DC
controlled
Signal level RS422 (TTL) for square wave incremental encoders
~1 Vss for sine incremental encoders
Current input Max. 250 mA
D-sub-connector
26-pin
1 GND encoder supply
2 +5 V encoder supply
3 reserved *
4 RS422 A +
5 RS422 A -
6 RS422 B +
7 RS422 B -
8 RS422 0 +
9 RS422 0 -
10 reserved *
11 Sense GND
12 Sense V
CC
13 reserved *
14 reserved *
15 reserved *
16 reserved *
17 Temperature +
18 Temperature -
19 reserved *
20 reserved *
21 reserved *
22 reserved *
21 reserved *
22 reserved *
23 reserved *
24 reserved *
25 reserved *
26 reserved *
* do not occupy