EasyManua.ls Logo

Baumuller b maXX 3000 - Page 132

Baumuller b maXX 3000
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connections
Instruction handbook b maXX BM3000, BM3200, BM3300
Document no. 5.11018.11 Baumüller Nürnberg GmbH
132
of 218
7.14
Encoder
evaluation with
HIPERFACE DSL
®
The encoders, which meet the following technical specifications, can be used:
Signal level HIPERFACE DSL
®
Current input Max. 250 mA
D-sub-connector
26-pin
1 GND encoder supply
2 10 V encoder supply
3 reserved *
4 reserved *
5 reserved *
6 reserved *
7 reserved *
8 reserved *
9 reserved *
10 reserved *
11 reserved *
12 reserved *
13 reserved *
14 reserved *
15 reserved *
16 reserved *
17 reserved *
18 reserved *
19 DSL-
20 DSL+
21 reserved *
22 reserved *
21 reserved *
22 reserved *
23 reserved *
24 reserved *
25 reserved *
26 reserved *
* do not occupy
NOTE!
The use of the standard accessory connector included in the accessory kit
HIPERFACE DSL
®
(part No. 460377) is required.