132 Transceivers 6200 Series DV14307.03 Issue 06 February 2021
3.6.4.1 Store
• The functions "LAST" and Store/Restore are only available if they are
enabled in the configuration setup* - ("MEM OPTIONS").
* (Details see "Configuration Setup" page 69).
The transceiver has two databases:
• The user channel database - it has 99 channels CH01…CH99 to store
frequencies with the possibility to apply a customized label (identifier)
with max. 10 alphanumeric characters.
• The last channel database - automatically stores the last used
frequencies.
Named and callable as LAST 1…LAST 9, the customized identifier will
be shown (if applied).
• You can store frequencies (in the range 118.000...136.9916 MHz) to any
channel with a push the "STO" key.
• All 99 channels are changeable.
With the start of the storage procedure, the device proposes the next free channel first.
• The label "FREE" shows together with the channel number if the selected
channel is vacant.
• A selected channel with a stored frequency has the label "USED".
• If the same frequency is stored a second time, then the existing data
(frequency, label/identifier data) is offered to store.
• If the frequency has no label attached, ten underscore digits are shown
to give in a label.
• The cursor automatically starts on the first position.
Overview - The user can store data to:
• Next free channel (offered from system).
• A selected free channel.
• A selected used channel (the existing data will be overwritten).
STO
_ _ _ _ _ _ _ _ _ _
125.875