EasyManua.ls Logo

Becker RT6201 - Environmental Conditions AR62 X1-(X2 X), RT62 X1-(X2 X)

Becker RT6201
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Description
Becker Avionics
Technical Data
32 Transceivers 6200 Series DV14307.03 Issue 06 February 2021
Environmental Conditions
Section
Cat.
Remarks
Radio Frequency Susceptibility
20
SW
-
Emission of Radio Frequency Energy
21
B
-
Lightning Induced Transients
Susceptibility
22 A1E3X
-
Lightning Direct Effects
23
X
No test done
Icing
24
X
No test done
Electrostatic Discharge (ESD)
25
A
-
Fire, Flammability
26
X
No test done
Environmental Conditions AR62X1-(X2X), RT62X1-(X2X)
The test was done in accordance with EUROCAE/RTCA Document ED-14F/DO-160F under
consideration of the recorded environmental categories and conditions:
Environmental Conditions
Section
Cat.
Remarks
Temperature and Altitude
4
C4
Ground Survival Low Temperature
4.5.1
-55 °C
Short-Time Operating Low Temperature 4.5.1
-20 °C
-40 °C for RT62X1
Operating Low Temperature 4.5.2
-20 °C
-40 °C for RT62X1
Ground Survival High Temperature
4.5.3
+85 °C
Short-Time Operating High Temperature
4.5.3
+70 °C
Operating High Temperature
4.5.4
+55 °C
In-flight Loss of Cooling
4.5.5
X
No forced cooling required
Altitude
4.6.1
C4
35 000 ft
Decompression
4.6.2
No test done
Overpressure
4.6.3
No test done
Temperature Variation
5
B
5 °C per minute
Humidity
6
A
Standard
Shock and Crash Safety
7
B
-
Operational Shocks
7.2
6 g
Crash Safety
7.3
Fixed-wing and helicopter, standard
Vibration 8
S
U
Curve M for fixed-wing aircraft
Curve G for helicopters
Explosion Atmosphere
9
X
No test done
Waterproofness
10
Y
Condensation