Becker Avionics
General Description
Technical Data
DV14307.03 Issue 06 February 2021 Transceivers 6200 Series 33
Environmental Conditions
Section
Cat.
Remarks
Fluids Susceptibility
11
X
No test done
Sand and Dust
12
X
No test done
Fungus Resistance
13
X
No test done
Salt Fog
14
X
No test done
Magnetic Effect
15
Z
< 1° deflection at 0.3 m
Power Input
16
B
-
Voltage Spike
17
A
-
Audio Freq. Conducted Susceptibility
18
B
-
Induced Signal Susceptibility
19
AC
Primary power DC
Radio Frequency Susceptibility
20
RW
-
Emission of Radio Frequency Energy
21
B
-
Lightning Induced Transients
Susceptibility
22 A1E3X
-
Lightning Direct Effects
23
X
No test done
Icing
24
X
No test done
Electrostatic Discharge (ESD)
25
A
-
Fire, Flammability
26
X
No test done
Environmental Conditions AR62X3-()
The test was done in accordance with EUROCAE/RTCA Document ED-14F/DO-160F under
consideration of the recorded environmental categories and conditions:
Environmental Conditions
Section
Cat.
Remarks
Temperature and Altitude
4
C4
Ground Survival Low Temperature
4.5.1
-55 °C
Short-Time Operating Low Temperature 4.5.1
-20 °C
-40 °C for RT62X1
Operating Low Temperature 4.5.2
-20 °C
-40 °C for RT62X1
Ground Survival High Temperature
4.5.3
+85 °C
Short-Time Operating High Temperature
4.5.3
+70 °C
Operating High Temperature
4.5.4
+55 °C
In-flight Loss of Cooling
4.5.5
X
No forced cooling required
Altitude
4.6.1
C4
35 000 ft
Decompression
4.6.2
No test done
Overpressure
4.6.3
No test done
Temperature Variation
5
B
5 °C per minute
Humidity
6
A
Standard