HYPERION - User Manual Bruker Optik GmbH
G
GIR objective ................... 99, 111, 112, 162
Checking the alignment .......................... 103
Generated images ................................. 102
Measurement procedure ........................ 107
Measuring mode (GIR) .......................... 101
Mirror optics .......................................... 100
Realigning ............................................ 104
Viewing mode (VIS) ............................... 101
H
Heatable sample holder ................. 116, 118
Specifications ....................................... 165
Heating/freezing stage THMS600 (Linkam)
.
116
, ................................................ 117, 164
Specifications ....................................... 164
HYPERION 1000
................. 25, 47, 60, 163
HYPERION 2000
...........25, 46, 47, 60, 163
HYPERION 3000
...........25, 46, 47, 60, 124
I
IMAC ...................................................... 123
In-focus LED
........................ 73, 90, 98, 141
Interpupillary scale
................................... 45
IR button
..................29, 66, 70, 73, 75, 150
IR polarizer
.............120, 122, 148, 151, 159
IR signal check
in reflection mode .................................... 68
in transmission mode ............................... 66
with ATR objective ................................... 72
IR signal intensity
Reducing ................................................ 76
Iris aperture for Koehler illumination
.. 37, 77
Iris aperture for Koehler illumination in reflec-
tion
...........................27, 37, 40, 41, 51, 149
Iris aperture for Koehler illumination in trans-
mission
...................38, 39, 41, 52, 149, 152
J
Joystick ...................................... 34, 35, 154
K
Knife-edge aperture .........27, 37, 51, 76, 77
Manual ............................................. 37, 40
Motorized ............................................... 40
Knobs for focussing
........................... 27, 28
Knobs for focussing the condenser
.......... 26
L
LCD monitor .... 25, 26, 27, 29, 46, 149, 150
LED display of the switching status ........... 46
Menu button ........................................... 46
ON / OFF switch ..................................... 46
Operating elements ................................. 27
Light path selector lever
42, 64, 68, 148, 149
Liquid nitrogen
..........................................59
Safety notes ............................................59
Low-voltage socket
...................................14
M
Manual knife-edge aperture ....... 40, 69, 115
Manual stage
............................. 31, 32, 162
Control elements ......................................32
Travel range ..........................................162
MCT detector
28, 30, 47, 48, 125, 130, 150,
163
Cooling ...................................................59
Dewar vacuum .......................................130
Evacuating the dewar .............................130
Nominal hold time ..................................130
Removing / reinstalling ...........................125
Measurement parameters
.......................167
Measuring mode
ATR objective ..........................................88
GIR objective .........................................101
Microscope ..............................................29
Microscope
Ambient requirement ..............................161
Dimensions .................................... 11, 161
Power supply .........................................161
Purging .................................................110
Spectral range .......................................161
Spectral resolution .................................161
Variants ..................................................25
Weight ..................................................161
Microscope lamp
.......................................28
Motorized knife-edge aperture
.. 40, 70, 113,
115
Motorized stage
...27, 31, 34, 116, 154, 162
Positioning accuracy ...............................162
Repeatability .........................................162
Reset ......................................................62
Travel range ........................... 31, 116, 162
O
Objective .................................... 43, 51, 161
Magnification .........................................161
Numerical aperture .................................161
Overview ...............................................111
Visible magnification ...............................161
Working distance ...................................161
ON/OFF switch
.........................................14
FPA detector .................................. 57, 128
Microscope ..............................................56
Spectrometer ...........................................56
Operating panel
........................................29
Optical adaptation box
76, 123, 124, 158, 159,
.................................................................160
Optical filter
.............................................160
Optics parameter
....................................168
OVP test protocol
......................... 67, 71, 74