COPYRIGHT
©
1999 CANON INC. CANON GP605/605V REV.0 JAN. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
7-85
CHAPTER 7 PICK-UP/FEEDING SYSTEM
[2]
[1]
[1]
[3]
[2]
Figure 7-F819
Figure 7-F820
10. Removing the U-Turn Sensor
1) Perform steps 1) through 8) given for the
removal of the duplexing reversal sensor.
2) Remove the screw [1], and detach the U-
turn sensor [2].
11. Removing the Pre-Confluence
Sensor
1) Disconnect the connector [1] from the
bottom of the duplexing unit; then, re-
move the screw [2], and detach the pre-
confluence sensor [3].