EasyManua.ls Logo

Case 1121F - Page 124

Case 1121F
366 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-CONTROLSANDINSTRUMENTS
Error
Item
Location
ofError
Detection
Message
1845y
JSCPilotpressureswitchstaysclosed(InputJSC8=1)allthoughJSSisactivated.With
lowpilotpressureonJSSvalvenosteeringwithJSSpossible.Errorisdisplayed
whenJSSactiveandPilotpressurestayslow.PilotDumpvalvestuckopenor
opencircuitorshorttogroundonJSSvalvepowersupply(ValveConnectorPin4).
OrshorttopoweronJSSpilotpressureswitchlinesorinputJSC/Pin8.
1846y
JSCStandardsteeringorbitrotankpressuretransducerswitchshorttopowerorshort
toground.
1847y
JSCJSCModeltypenotavailable,nomodeltypeinformationavailableinJSC,
probablymissinginformationfromAIC.
1850y
JSCJSSjoystickPins2,4or6shorttoground,shorttobatteryoropencircuit.OrJSS
joystickinternalfailure.
1852y
JSCJSSjoystickPins5opencircuit.OrJSSjoystickinternalfailure.
1860y
JSCCANtimeoutofC5.EdetectedbyJSC.
1861y
JSCCANtimeoutofAICdetectedbyJSCController.
1863y
AICInternalmalfunctiontransmissioncontroller.TCUmessageJSSF-N-Rdissabled
orJSSF-N-Rnotactivated.
9128y
AICCANtimedoutduringoperation.
9134y
AICCANtimedoutduringoperationC5.EdetectedbyAIC.
9135y
AICCANtimedoutduringoperationJSCdetectedbyAIC.
3-58