7-MAINTENANCE
Batteryelectrolytelevel[60637245]
WARNING
Hazardouschemicals!
Batteryelectrolytecontainssulfuricacid.Contactwithskinandeyescouldresultinsevereirritation
andburns.Alwayswearsplash-proofgogglesandprotectiveclothing(glovesandaprons).Wash
handsafterhandling.
Failuretocomplycouldresultindeathorseriousinjury.
W0006A
WARNING
Batteryacidcausesburns.Batteriescontainsulfuricacid.
Avoidcontactwithskin,eyesorclothing.Antidote(external):Flushwithwater.Antidote(eyes):ush
withwaterfor15minutesandseekmedicalattentionimmediately.Antidote(internal):Drinklarge
quantitiesofwaterormilk.Donotinducevomiting.Seekmedicalattentionimmediately.
Failuretocomplycouldresultindeathorseriousinjury.
W0111A
WARNING
Chemicalhazard!
Batteryposts,terminals,andrelatedaccessoriescontainleadandleadcompounds.Washhandsafter
handling.
Failuretocomplycouldresultindeathorseriousinjury.
W0349A
Checkbatteryuidlevelandspecicgravity
Checkthebatteryuidlevelevery500hoursofoperation
ormoreoftenifconditionsaresevere.Thebatteryuidcan
decreasewithhightemperatures.
1.Insertaatbladescrewdriverintoslotsatthetopof
batterycaps.Removethecellcapsandcheckthelevel
ineachbatterycell.Thelevelshouldbenolessthan
4.8mm(0.2in)fromthebottomofthecell.Adddis-
tilledwaterifnecessary,theninstallthecellcaps.
NOTE:Wipethetopofthebatteryorusecompressedair
toremovedust.Usecarewhenremovingcapsanddonot
allowdirtorcontaminantstoenterthebatterycells.
NOTICE:Continuoususeofthebatterywithlowuidwill
lowerbatteryperformance.
2.Iftheterminalsaredirty,washwithwarmwater.Rein-
stalltheterminals,applygreaseorsprayrustpreven-
tivesolutiontocreategoodconnections.
3.Iftheterminalisoxidized,polishitwithawirebrushor
emerypaper.
NOTE:Measurethespecicgravityofbatteryuidwitha
gravimeter.Themeasuredvaluewillvarydependingon
theambienttemperature.
RCPH11WHL330AAH1
7-102