Remote Operation
5-19
6. SOURce:CURRent:LIMit:{HIGH/LOW}
Description:
Sets the output current range.
Syntax:
SOURce:CURRent:LIMIT:HIGH <NRf+>[suffix]
SOURce:CURRent:LIMIT:LOW <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:CURR:LIMIT:HIGH 60.0 It sets the output current
range to 60A maximum.
SOUR:CURR:LIMIT:LOW 20.0 It sets the output current
range to 20A minimum.
Query Syntax:
SOUR:CURR:LIMIT:HIGH? [{MAX/MIN}]
SOUR:CURR:LIMIT:LOW? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Amp]
Query Example:
SOUR:CURR:LIMIT:HIGH? It returns the current high
limit.
SOUR:CURR:LIMIT:HIGH? MAX It returns the max. current
can be set.
Return Example:
6.000000e+01
Note
Source and Load current share this setting.
7. SOURce:CURRent:PROTect:HIGH
Description:
Sets the current range for over current protection.
Syntax:
SOURce:CURRent:PROTect:HIGH <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:CURR:PROT:HIGH 60.0 It sets the high limit to 60A
for current output protection.
Query Syntax:
SOUR:CURR:PROT:HIGH? [{MAX/MIN}]
Return Parameter:
<NRf+> [Unit=Amp]
Query Example:
SOUR:CURR:PROT:HIGH? It returns the high limit of
current protection.
SOUR:CURR:PROT:HIGH? MAX It returns the max. over
current protection.
Return Example:
6.000000e+01
8. SOURce:CURRent:SLEW
Description:
Sets the rising or falling slew rate (amp/ms) of output current.
Syntax:
SOURce:CURRent:SLEW <NRf+>[suffix]
Parameter:
Refer to individual spec for valid numeric range.
Example:
SOUR:CURR:SLEW 0.01 It sets the output current slew
rate to 0.01 Amp/ms.
SOUR:CURR:SLEW 1.00 It sets the output current slew
rate to 1.00 Amp/ms.
Query Syntax:
SOUR:CURR:LIMIT:HIGH? [{MAX/MIN}]
SOUR:CURR:LIMIT:LOW? [{MAX/MIN}]
Return Parameter:
< NRf+> [Unit=Amp/ms]
Query Example:
SOUR:CURR:SLEW? It returns the current slew rate.
SOUR:CURR:SLEW? MAX It returns the max. current slew
rate.
Return Example:
1.000000e+00
Note
Source and Load current share this setting.
9. SOURce:POWer