7-7
Catalyst 3750 Metro Switch Software Configuration Guide
78-15870-01
Chapter 7 Configuring Switch-Based Authentication
Protecting Access to Privileged EXEC Commands
Beginning in privileged EXEC mode, follow these steps to establish a username-based authentication
system that requests a login username and a password:
To disable username authentication for a specific user, use the no username name global configuration
command. To disable password checking and allow connections without a password, use the no login
line configuration command.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
username name [privilege level]
{password encryption-type password}
Enter the username, privilege level, and password for each user.
• For name, specify the user ID as one word. Spaces and quotation
marks are not allowed.
• (Optional) For level, specify the privilege level the user has after
gaining access. The range is 0 to 15. Level 15 gives privileged EXEC
mode access. Level 1 gives user EXEC mode access.
• For encryption-type, enter 0 to specify that an unencrypted password
will follow. Enter 7 to specify that a hidden password will follow.
• For password, specify the password the user must enter to gain access
to the switch. The password must be from 1 to 25 characters, can
contain embedded spaces, and must be the last option specified in the
username command.
Step 3
line console 0
or
line vty 0 15
Enter line configuration mode, and configure the console port (line 0) or
the VTY lines (line 0 to 15).
Step 4
login local Enable local password checking at login time. Authentication is based on
the username specified in Step 2.
Step 5
end Return to privileged EXEC mode.
Step 6
show running-config Verify your entries.
Step 7
copy running-config startup-config (Optional) Save your entries in the configuration file.