GR740-UM-DS, Nov 2017, Version 1.7 111 www.cobham.com/gaisler
GR740
10.6.5 FT diagnostic checkbits register
Table 99. 0x28 - FTDC - FT diagnostic checkbits register
10.6.6 FT diagnostic data register
Table 100.0x2C - FTDD - FT diagnostic data register
10.6.7 FT boundary address register
Table 101.0x30 - FTBND - FT boundary address register
31 24 23 16 15 8 7 0
CBD CBC CBB CBA
****
rw rw rw rw
31: 24 Checkbits for part D of 64-bit data word (CBD) - (undefined for code B)
23: 16 Checkbits for part C of 64-bit data word (CBC) - (undefined for code B)
15: 8 Checkbits for part B of 64-bit data word (CBB)
7: 0 Checkbits for part A of 64-it data word. (CBA)
Note that this is a "virtual" register backed by memory, an access to it will result in a corresponding access to the
memory location configured in the FTDA register.
31 0
DATA
*
r
31: 0 Uncorrected data (DATA) - For 32-bit address set in FTDA register
Note that this is a "virtual" register backed by memory, an access to it will result in a corresponding access to the
memory location configured in the FTDA register.
31 32 0
FTBND(31:3) RESERVED
00
rw 0
31: 3 Code boundary address (FTBND) - 64-bit aligned. Field contains address bits 31:3. Bits 2:0 are
always zero.
2: 0 RESERVED