19.9.4 Memory configuration register 7 (MCFG7)
MCFG7 contains fields to control bus ready timeout.
Table 368. Memory configuration register 7
31 16
BRDYNCNT
0
rw
15 0
BRDYNRLD
0
rw
31 : 16 Bus ready count (BRDYNCOUNT) - Counter value. If this register is written then the counter shall
be written with the same value as BRDYNRLD.
15: 0
Bus ready reload value (BRDYNRLD) - Reload value for BRDYNCNT