EasyManuals Logo

COBHAM GR740 User Manual

COBHAM GR740
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #379 background imageLoading...
Page #379 background image
GR740-UM-DS, Nov 2017, Version 1.7 379 www.cobham.com/gaisler
GR740
Table 492. 0x074 - TR4 - Time Stamp Elapsed Time 4 Rx
31 24 23 0
TR4 RESERVED
00
rr
31: 24 Time Stamp Elapsed Time 4 Rx (TR4) - Time stamped local ET value (128 to 135) when distributed inter-
rupt received.
23: 0 RESERVED
Table 493. 0x080 - TTPFTX - Time-Stamp SpaceWire Time-Code and Preamble Field Tx
31 24 23 16 15 0
TSTC RESERVED TTPF
00
0x2f00
rw r r
31: 24 Time stamp time code (TSTC) - Time stamp on this time-code value, used for time stamping when
this register matched with SpaceWire Time-Codes
. The mask for this matching is available in con-
figuration register 3.(only for initiator)
23: 16 RESERVED
15: 0 Time stamp Preamble Field (TTPF) - The number of coarse and fine time implemented can be
obtained from this Preamble Field.
Table 494. 0x084 - TT0 - Time Stamp Elapsed Time 0 Tx
31 0
TT0
0
r
31: 0 Time Stamp Elapsed Time 0 Tx (TT0) - Time stamped local ET value (0 to 31) when distributed
interrupt transmitted.
Table 495. 0x088 - TT1 - Time Stamp Elapsed Time 1 Tx
31 0
TT1
0
r
31: 0 Time Stamp Elapsed Time 1 Tx (TT1) - Time stamped local ET value (32 to 63) when distributed
interrupt transmitted.
Table 496. 0x08C - TT2 - Time Stamp Elapsed Time 2 Tx
31 0
TT2
0
r
31: 0 Time Stamp Elapsed Time 2 Tx (TT2) - Time stamped local ET value (64 to 95) when distributed interrupt
transmitted.