EasyManua.ls Logo

Compaq AlphaServer ES45 1B User Manual

Compaq AlphaServer ES45 1B
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #233 background imageLoading...
Page #233 background image
Firmware 5-69
5.14.20 pk*0_fast
The pk*0_fast environment variable enables fast SCSI to perform in
either standard or fast mode.
If the system has at least one fast SCSI device, set the default controller speed
to fast SCSI (1). Devices on a controller that connects to both standard and fast
SCSI devices will perform at the appropriate rate for the device. If the system
has no fast SCSI devices, set the default controller speed to standard SCSI (0).
If a fast SCSI device is on a controller set to standard, it will perform in stan-
dard mode.
To list the controllers on your system, enter the show device command. SCSI
controllers begin with the letters “pk,” for example, pka0. The third letter is the
adapter ID for the specific SCSI controller. Replace the asterisk with the
adapter ID letter when entering the set pk*0_fast command.
The value of set pk*0_fast takes effect only after you reset the system by press-
ing the Reset button or by issuing the init command.
Syntax
set pk*0_fast scsi_speed
The options for scsi_speed are:
0
The controller is in standard SCSI mode.
1 (default)
The controller is in fast SCSI mode.
Example
P00>>> set pkb0_fast 1
P00>>> init
.
.
.
P00>>> show pkb0_fast
P00>>> pkb0_fast 1

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Compaq AlphaServer ES45 1B and is the answer not in the manual?

Compaq AlphaServer ES45 1B Specifications

General IconGeneral
Processor Speed1 GHz
MemoryUp to 32 GB
Memory TypeDDR SDRAM
Expansion Slots6 PCI slots
NetworkIntegrated 10/100 Ethernet
Operating SystemTru64 UNIX, OpenVMS
Form FactorRackmount
ProcessorAlpha EV68
ChipsetTsunami chipset
StorageUp to 6 hot-swap SCSI drives
I/O Slots6 PCI slots
Power SupplyRedundant hot-swap power supplies

Summary

Operation

Powering Up the System

Provides steps to power on the AlphaServer ES45 system.

SRM Console

Introduction to the SRM command-line interface for system management.

Setting Console Security

Procedures for setting console passwords and secure mode.

Updating Firmware

Methods for updating system firmware via CD-ROM or network.

Booting and Installing an Operating System

Setting Boot Options

Configuring boot devices, flags, and network protocols via SRM.

Starting a Tru64 UNIX Installation

Procedure for installing the Tru64 UNIX operating system.

Configuring and Installing Components

Before Installing Components

Prerequisites and safety precautions before installing components.

Removing and Replacing Power Supplies

Procedure for removing and replacing system power supplies.

Installing CPUs

Step-by-step guide for installing CPU modules.

Memory Configuration

Rules and considerations for memory configuration and DIMM installation.

Installing Universal Hard Disk Drives

Procedure for installing hot-pluggable universal hard disk drives.

Firmware

Remote Management

Troubleshooting

Related product manuals