6.6.1 Displaying the System Status
TheRMCstatuscommanddisplaysthesystemstatusandthecurrent
RMC settings. Table 6–1 explains the status fields. See Section 6.8 for
information on the commands used to set the status fields.
RMC> status
PLATFORM STATUS
On-Chip Firmware Revision: V1.0
Flash Firmware Revision: V1.6
Server Power: ON
System Halt: Deasserted
RMC Power Control: ON
Escape Sequence: ^[^[RMC
Remote Access: Disabled
RMC Password: not set
Alert Enable: Disabled
Alert Pending: NO
Init String:
Dial String:
Alert String:
Com1_mode: THROUGH
Last Alert: Fan 1 failed
Logout Timer: 20 minutes
User String:
RMC>