Troubleshooting 7-17
7.4.6 Show Power Command
Use the SRM show power command to determine whether the failure of
a system running Tru64 UNIX or OpenVMS was related to a fan,
temperature, or power supply problem. You can use this command if
you are able to restart the system. Otherwise, invoke RMC and use the
env command.
Example 7–8 Show Power Command
P00>>> show power
Status
Power Supply 0 Good
Power Supply 1 Good
Power Supply 2 Not Available
System Fan 1 Good
System Fan 2 Good
System Fan 3 Bad
System Fan 4 Good
System Fan 5 Good
System Fan 6 Good
CPU 0 Temperature Warning
CPU 1 Temperature Good
CPU 2 Temperature Good
CPU 3 Temperature Good
Zone 0 Temperature Good
Zone 1 Temperature Good
Zone 2 Temperature Good
P00>>>
Power supplies. Power supply 2 is not installed.
System fans. Fan 3 is not working.
Temperature sensors on CPUs. CPU 0 is above threshold.
Temperature sensors on PCI backplane.