EasyManua.ls Logo

Compaq AlphaServer ES45 1B

Compaq AlphaServer ES45 1B
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting 7-17
7.4.6 Show Power Command
Use the SRM show power command to determine whether the failure of
a system running Tru64 UNIX or OpenVMS was related to a fan,
temperature, or power supply problem. You can use this command if
you are able to restart the system. Otherwise, invoke RMC and use the
env command.
Example 7–8 Show Power Command
P00>>> show power
Status
Power Supply 0 Good
Power Supply 1 Good
Power Supply 2 Not Available
System Fan 1 Good
System Fan 2 Good
System Fan 3 Bad
System Fan 4 Good
System Fan 5 Good
System Fan 6 Good
CPU 0 Temperature Warning
CPU 1 Temperature Good
CPU 2 Temperature Good
CPU 3 Temperature Good
Zone 0 Temperature Good
Zone 1 Temperature Good
Zone 2 Temperature Good
P00>>>
Power supplies. Power supply 2 is not installed.
System fans. Fan 3 is not working.
Temperature sensors on CPUs. CPU 0 is above threshold.
Temperature sensors on PCI backplane.

Table of Contents